4-26 Description of Diagnostic Letters B..., C..., D... and A... ECODRIVE03 SMT-02VRS
DOK-ECODR3-SMT-02VRS**-WA01-EN-P
D400 Positive stop drive procedure command
When the positive stop drive procedure command is activated, all
controller monitoring which would result in an error message for class 1
diagnostic caused by blocking the drive with a positive stop is turned off.
Cause:
Command D400 Positive stop drive procedure command was
activated.
See also the functional description: "Positive stop drive procedure"
D401 ZKL1-Error at command start
Cause:
A class 1 diagnostic error was discovered while starting the command
"Positive stop drive procedure" As a result, the command could not be
executed.
Remedy:
Eliminate the cause of the error, clear the error, and start the command
again.
See also the functional description: "Positive stop drive procedure"
D500 Command Get mark position
The P-0-0014, D500 Command determine marker position command
can be used for checking the correct acquisition and position of the
reference marker of an incremental measuring system. The "d5“ display
shows that the command has been activated.
Cause:
The Determine marker position command has been activated.
See also the functional description: "Functional principle of command
detect marker position"
D501 Incremental encoder required
Cause:
The command has been started for a measuring system that does not
possess real reference markers. These include measuring systems such
as DSF, EnDat, SSI or resolver measuring systems.
Remedy:
Check whether the correct encoder has been selected in S-0-0147,
Homing parameter.
Employ an encoder system with real reference markers.
See also the functional description: "Functional principle of command
detect marker position""