ECODRIVE03 SMT-02VRS Description of Diagnostic Letters B..., C..., D... and A... 4-3
DOK-ECODR3-SMT-02VRS**-WA01-EN-P
B010 5 pulses found, but min. distance to move not reached
Five pulses if travel path is too short, interference or pulse wire encoder is
defective.
B011 SDAI goes immeadiately back to 0, old PIC version
Signal SDAI goes back to "0", old PIC, setting not possible.
B012 Master password required
No master password has been entered.
B013 Shaft does not turn as expected
The shaft does not turned as planned.
B100 Command Release motor holding brake
The command P-0-0542, Command Release motor holding brake has
been activated.
See also the functional description: "Motor Holding Brake".
B101 Command not enabled
The command P-0-0542, Command Release motor holding brake has
been activated without prior enabling via the parameter P-0-0538, Bit 8.
See also the functional description: "Motor Holding Brake".
B200 Brake check command
The command P-0-0542, Command to open motor holding brake was
activated.
See also the functional description: "Motor Holding Brake"
B201 Brake check only with drive enable
P-0-0541, B200 command brake monitor was activated and the drive
enable was not activated.
See also the functional description: "Motor Holding Brake"