Matrix VISIONPRO System Manual 116
• To assign a Denied List to a CDC table, dial,
4916-1-CDC Table-Denied List
Where,
CDC Table is from 0 to 3.
Denied List is from 0 to 7.
• To assign the same Denied List to all CDC tables at once, dial,
4916-*-Denied List
• To assign a CDC Table to another station, dial the command 4920 as described at the beginning of
configuration.
• To restore the default settings of a CDC table, dial,
4901-1-CDC Table-#
Where,
CDC Table is from 0 to 3.
• To restore the default settings of all CDC Tables at once, dial,
4901-*-#
• Exit SE mode.
Example: Program station 21 (software port number 00) for the following requirement:
Disconnect all calls after 180 seconds.
Solution:
Assign default CDC table 3 to station 21. Dial 4920-1-00-3 in SE mode.
Since default CDC Timer is 160 seconds and 20 seconds are added as warning time, the calls will get disconnected
after 180 seconds. Hence no programming is required.