41 Matrix VISIONPRO System Manual
By default, Flash timer index is 6.
If the Flash Timer range is configured as 70-100ms, Pulse dialing for that particular SLT phone will not
work.
• To configure the same Flash Timer value for all stations, dial,
4102-*-Flash Timer Index
• To configure the Digit Padding for a station, dial,
4104-1-Station-Count
Where,
Station is the software port number of the station from 00 to 07.
Count is from 0 to 9.
By default, the count is 9 for each station.
• To configure the same digit padding count for all stations at once, dial,
4104-*-Count
If count is programmed as 0, the calling party’s number will be displayed the same which is received. If the
count is programmed between 1 to 9, the digit length of the calling party’s number displayed will be equal
to the count. For example, if the count value is programmed as 4 and station number 21 is calling, then two
zeroes will be padded to 21 to maintain the length 4. The display will be ‘2100’.
• To configure the AC Impedance for a station, dial,
4105-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Default AC impedance is 600
• To configure the same AC Impedance for all stations at once, dial,
4105-*-Code
• To configure the Transmit Gain for a station, dial,
4106-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
8 101-800
9 101-900
Code Meaning
0 600
1 900
2 350 + (1000 || 0.21F)
3 220 + (820 || 120nF)
Code Gain (in dB)
00 -3
01 0 (Default)
02 3
Flash Timer
Index
Flash Timer value
in ms