Matrix VISIONPRO System Manual 44
Default is None
To configure the same Answer Signaling for all stations at once, dial,
4111-*-Code
To configure the Disconnect Signaling for a station, dial,
4112-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Default is None
To configure the same Disconnect Signaling for all stations at once, dial,
4112-*-Code
To configure the Open Loop Disconnect Timer for a station, dial,
4113-1-Station-Code
Where,
Station is the software port number of the station from 00 to 07.
Default is 7 (476ms)
To configure the same Open Loop Disconnect Timer for all stations at once, dial,
4113-*-Code
To configure the Loop Current for a station, dial,
4116-1-Station-Code
Where,
Code Disconnect Signal
0 None
1 Polarity Reversal
2 Open Loop
Code
Open Loop Disconnect
Timer (in ms)
01 68
02 136
03 204
04 272
05 340
06 408
07 476
08 544
09 612
10 680
11 748
12 816
13 884
14 952