Matrix VISIONPRO System Manual 70
Default code is 6.
To configure the same Flash Timer for all trunks, dial,
3123-*-Code
To configure the ON-Hook Speed for a trunk, dial,
3126-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Default code is 0.
To configure the same ON-Hook Speed for all trunks, dial,
3126-*-Code
To configure the OFF-Hook Speed for a trunk, dial,
3127-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Default code is 3.
To configure the same OFF-Hook Speed for all trunks, dial,
3127-*-Code
To configure the Current Limiting Mode for a trunk, dial,
3128-1-Trunk-Flag
Where,
4 400ms
5 500ms
6 600ms
7 700ms
8 800ms
9 900ms
Code ON-Hook Speed
0 < 0.5ms
13ms
2 26ms
Code OFF-Hook Speed
0 512ms
1 128ms
2 64ms
38ms
Code Flash Timer

Table of Contents