OPTIONAL FUNCTIONS
www.maxcessintl.com
CYGNUS
MI 850A316 1 B
Page 30 of 66
8.7 Alarms (optional)
The Alarm Output is used to detect low or high tension and provide indication to an outside device. It is typically
used for “Web Break Detection”.
(Home Screen)
Select Maximum output current
Set whether Alarm is used of alarm signal. Typically 5
mADC for 5 VDC logic and 100 mADC
for
24 VDC logic.
Enter % of tension setpoint
At which alarm actuates.
Below 100% for low tension
Above 100% for high tension. Set time delay before alarm
activates. (Default is 0 seconds)