Document reference MAVM600MK2MPS-QS/E QUICK START MANUAL
Edition 2 - February 2021 VM600
Mk2
machinery protection system (MPS)
xi
Hazardous voltages and the risk of electric shock
Hot surfaces and the risk of burning
Heavy objects and the risk of injury
HAZARDOUS VOLTAGES EXIST WITHIN A VM600
Mk2
/VM600 RACK.
W
HEN A MODULE/CARD, PANEL OR POWER SUPPLY IS REMOVED FROM A
VM600
Mk2
/VM600 RACK, THE RACK BACKPLANE CONTAINING HAZARDOUS
VOLTAGES
IS EXPOSED AND THERE IS THE RISK OF ELECTRIC SHOCK, AS INDICATED
BY
THE USE OF THE FOLLOWING WARNING LABEL ON THE EQUIPMENT:
R
EGARD ANY EXPOSED COMPONENT, CONNECTOR OR PRINTED CIRCUIT BOARD (PCB)
AS A POSSIBLE SHOCK HAZARD AND DO NOT TOUCH WHEN ENERGISED.
F
OR SAFETY REASONS, ANY VM600
Mk2
/VM600 RACK SLOT (MODULE POSITION) NOT
POPULATED
BY A MODULE MUST BE COVERED BY A BLANK PANEL.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN DEATH, SERIOUS INJURY,
AND/OR EQUIPMENT DAMAGE.
HOT SURFACES CAN EXIST WITHIN AND ON A VM600
Mk2
/VM600 RACK.
D
EPENDING ON THE AMBIENT OPERATING TEMPERATURE AND POWER CONSUMPTION,
AND THE INSTALLATION AND COOLING OF A VM600
Mk2
/VM600 RACK, THE TOP OF
THE
RACK CAN BECOME HOT TO TOUCH AND THERE IS THE RISK OF BURNING WHEN
HANDLING
THE RACK, AS INDICATED BY THE USE OF THE FOLLOWING WARNING LABEL
ON
THE EQUIPMENT:
R
EGARD THE TOP OF A VM600
Mk2
/VM600 RACK AS A HOT SURFACE AND DO NOT
TOUCH
UNLESS COOL.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN INJURY.
A FULLY POPULATED VM600
Mk2
/VM600 SYSTEM RACK (ABE04X) WITH RPS6U
RACK POWER SUPPLIES AND MODULES INSTALLED IS A HEAVY OBJECT.
D
EPENDING ON THE NUMBER OF RPS6U RACK POWER SUPPLIES AND MODULES
INSTALLED
, A VM600
Mk2
/VM600 SYSTEM RACK CAN BE TOO HEAVY TO HANDLE
MANUALLY
BY ONE PERSON AND THERE IS THE RISK OF INJURY DURING INSTALLATION
OR
REMOVAL. ACCORDINGLY, A FULLY POPULATED VM600
Mk2
/VM600 SYSTEM
RACK
SHOULD BE CONSIDERED AS A HEAVY OBJECT THAT REQUIRES TWO PEOPLE TO
LIFT
, LOWER OR OTHERWISE HANDLE MANUALLY.
A
LTERNATIVELY, THE RPS6U RACK POWER SUPPLIES (THE HEAVIEST SYSTEM
COMPONENTS
AND EASILY REMOVABLE), AND THEN THE MODULES AS NECESSARY,
CAN BE REMOVED FROM THE RACK IN ORDER TO REDUCE THE WEIGHT AND ALLOW
ONE
PERSON TO SAFELY HANDLE MANUALLY.
F
AILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN INJURY.

Table of Contents

Other manuals for Meggitt vibro-meter VM600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meggitt vibro-meter VM600 and is the answer not in the manual?

Meggitt vibro-meter VM600 Specifications

General IconGeneral
BrandMeggitt
Modelvibro-meter VM600
CategoryProtection Device
LanguageEnglish