Page #80 background imageLoading...
Page #80 background image
QUICK START MANUAL Document reference MAVM600MK2MPS-QS/E
VM600
Mk2
machinery protection system (MPS) Edition 2 - February 2021
3-10
Common VibroSight Protect tasks
OVERVIEW OF VM600
Mk2
MACHINERY PROTECTION SYSTEM (MPS) SOFTWARE
The Serial number and/or IP address for a MPC4
Mk2
module can be obtained using
VibroSight System Manager (see 3.3.3 Displaying information about a MPC4
Mk2
module).
Once the IP address has been configured, the Blink front panel LEDs control can be used to
verify communications between VibroSight Protect and the MPC4
Mk2
module
(see 3.4.2 Identifying a MPC4
Mk2
module in a VM600
Mk2
/VM600 rack using
VibroSight Protect).
3.4.2 Identifying a MPC4
Mk2
module in a VM600
Mk2
/VM600 rack using
VibroSight Protect
VibroSight Protect can be used to identify a MPC4
Mk2
module in a VM600
Mk2
/VM600 rack
by making the LEDs on the front panel of the module blink (flash).
This can be used to help physically identify a module in a rack, which can be useful, for
example, to identify a module before removing it from the rack or adding connections to the
corresponding input / output module in the rear of the rack.
1- Start VibroSight Protect.
2- On the Configure tab/page, select the MPC4
Mk2
rack slot from the view of the rack (top).
Alternatively, select the MPC4
Mk2
rack slot in the System window (right).
The main window (centre) updates to display the information for the MPC4
Mk2
module.
3- In the main window (centre), under Network settings, click the Blink front panel LEDs
control.
VibroSight Protect will display a window to confirm LED test done successfully and all
LEDs on the front panel of the MPC4
Mk2
module will blink , holding each LED
state for approximately 2 seconds.
After the LED test is finished, which takes a total of approximately 20 seconds, the LEDs on
the front panel of the MPC4
Mk2
module will resume normal LED operation
(see 2.2.1 MPC4
Mk2
module LEDs).
See also 3.3.2 Identifying a MPC4
Mk2
module in a VM600
Mk2
/VM600 rack using
VibroSight System Manager.

Table of Contents

Other manuals for Meggitt vibro-meter VM600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Meggitt vibro-meter VM600 and is the answer not in the manual?

Meggitt vibro-meter VM600 Specifications

General IconGeneral
BrandMeggitt
Modelvibro-meter VM600
CategoryProtection Device
LanguageEnglish