252
BIT2
1
Running (the direction depends on the
function code)
0
Other status of running (see control
character 1)
BIT15~BIT3 0 Reserved
Note
The overall word 2 is valid only when its BIT0 is valid.
2. Status parameters
Register
address
Parameter name Remarks
0x6500 Status word 1 of drive
0x6501 Actual running value of current main reference Current running frequency
0x6502 Slave model
0x6503 Drive series number
0x6504 Software version
0x6505 Current running frequency
0x6506 Output current
0x6507 Output voltage
0x6508 Output power
0x6509 Rotating speed in running
0x650A Line speed in running
0x650B Analog process closed loop feedback
0x650C Bus voltage
0x650D Reserved
0x650E Output torque
0x650F Status of digital input/output terminal
BIT0~BIT7: X1~X8;
BIT10~BIT13: Y1/Y2/RO1/RO2
0x6510 Reserved
0x6511 Running frequency after compensation
0x6512 The 1st running fault
0x6513 The 2nd running fault
0x6514 The 3rd (the latest one) running fault
0x6515 Setting running frequency
0x6516 Setting rotating speed