36
Fig. 3-13 The wiring mode when using the internal +24V power supply of the drive
2) When using the external power supply (which shall meet the UL CLASS 2 standard, and 4A fuse shall
be installed between the power supply and the interface), the wiring mode is as shown in Fig.3-14 (be
sure to remove the short circuit plate between PLC and P24).
Fig. 3-14 The wiring mode when using the external power supply
2. Source (drain) mode
1) When the internal +24V power supply is used and the external controller is the NPN common emitter
output, the wiring mode is as shown in Fig. 3-15.
Fig. 3-15 The source connecting mode when using the internal +24V power supply of the drive