NON-BIGFOOT GEAR HOUSING
Page 6A-34 90-828631R3 MARCH 1999
9. Apply Loctite 271 to O.D. of large diameter seal.
10. With seal lip FACING TOWARDS SMALL SHOULDER of Mandrel 91-817007, press
seal into carrier until mandrel bottoms on carrier.
52863
7
7
Loctite “271” (92-809819)
91-817007
b
a
a-Seal
b-Mandrel (91-817007)
Installation Note: If service tools are not available, the following reference dimensions ap-
ply for installing bearing and seals to proper depths.
51275
.82 in. (20 mm)
a
a-Bearing
51275
.04 in. (1mm)
.44 in. (11mm)
a
b
a-Oil Seal (Install with Lip Down)
b-Oil Seal (Install with Lip Up)