EasyManuals Logo

Mercury MerCruiser D2.8L D-Tronic User Manual

Mercury MerCruiser D2.8L D-Tronic
878 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #688 background imageLoading...
Page #688 background image
SEAWATER COOLING SYSTEM SERVICE MANUAL NUMBER 22
Page 6A-6 90-860074--1 FEBRUARY 2002
Seacock
If a seacock is being used, it must be installed between water pickup and seawater pickup
pump (or seawater strainer), to allow operator to shut off the seawater in case of a leak or
when boat is not in use. This will also allow the operator to flush or drain the engine, or clean
the sea strainer while boat is in the water. Install seacock in an area where it will be easily
accessible and support adequately to prevent hose fatigue.
To prevent restricting water flow seacock used must have an internal cross-sectional area
equal to or greater than hose.
Refer to Specifications.
70355
b
c
a
Through The Hull Components Shown - All Similar
a-Wire Reinforced Hose
b-Seacock
c-Seawater Pickup
Seawater Strainer
The strainer, if equipped, must be of sufficient size to ensure that an adequate supply of
water will be maintained for cooling engine. A minimum flow rate is required.
Refer to Specifications.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mercury MerCruiser D2.8L D-Tronic and is the answer not in the manual?

Mercury MerCruiser D2.8L D-Tronic Specifications

General IconGeneral
BrandMercury
ModelMerCruiser D2.8L D-Tronic
CategoryEngine
LanguageEnglish

Related product manuals