Page 102 of 104
Peripherals > Infeed Flow Monitor > Numeric Data ). Feeder
must be in Auto and must be running.
When a loss of flow is detected (logical input “Low Infeed Flow”
turns on, an internal totalizer is started. If this totalizer exceeds
the set amount, the logical output “Empty Pipe” is set.
Drive Check related. Present when “Drive Feedback” is enabled (see Main Menu >
Advanced Setup > Configuration > Drive Feedback).
Belt Drive Ovld Drive Overload. Time delayed version of “Belt Drv Overld” input.
Time set by “Overld On Delay” parameter in Feeder Peripherals
menu.
Belt Drive NAS Drive not at speed when required. Time allowed for drive to
come up to speed set by “Not at Spd On Delay” parameter in
Feeder Peripherals menu.