Peripherals > Infeed Flow Monitor > Numeric Data ). Feeder
must be in Auto and must be running.
When a loss of flow is detected (logical input “Low Infeed Flow”
turns on, an internal totalizer is started. If this totalizer exceeds
the set amount, the logical output “Empty Pipe” is set.
Drive Check related. Present when “Drive Feedback” is enabled (see Main Menu >
Advanced Setup > Configuration > Drive Feedback).
Belt Drive Ovld Drive Overload. Time delayed version of “Belt Drv Overld” input.
Time set by “Overld On Delay” parameter in Feeder Peripherals
menu.
Belt Drive NAS Drive not at speed when required. Time allowed for drive to
come up to speed set by “Not at Spd On Delay” parameter in
Feeder Peripherals menu.

Table of Contents

Other manuals for MERRICK Genetix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MERRICK Genetix and is the answer not in the manual?

MERRICK Genetix Specifications

Operating Environment IconOperating Environment
maximum ambient temperature50°C (122°F)
minimum ambient temperature-10°C (14°F)
Power IconPower
supply voltage24 VDC +/- 1V
power consumption8W nominal, 12W maximum
power dissipation5W nominal, 10W maximum
Loadcell Inputs IconLoadcell Inputs
excitation voltage5 VDC
excitation current300mA (max)
Tachos IconTachos
supply voltage5 VDC
supply current400mA, maximum (total)
Analog Inputs IconAnalog Inputs
input impedance (current input)200 ohms
input impedance (voltage input)100Kohms
Digital Inputs IconDigital Inputs
input impedance at 24 VDC7.5 KΩ
input impedance at 120 VAC64 KΩ
input impedance at 240 VAC120 KΩ
Digital Outputs IconDigital Outputs
contact ratings (AC)5A, 250 VAC
contact ratings (DC)5A, 30 VDC
External Mechanical Totalizer IconExternal Mechanical Totalizer
contact ratings (AC)120mA, 240 VAC
contact ratings (DC)120mA, 24 VDC