EasyManua.ls Logo

Miele CVA615 - 5.20 Brew Unit - Removal (in start;home position)

Miele CVA615
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
58
CVA615 Coffee System
9. Observe the numeric value in the lower right corner of the
display.
If a value of “350” is displayed; proceed to step 14.
If the value is not 350; proceed to step 10.
10. Press the Small Coffee Button 1 time. A blinking box will
appear at the end of numeric value.
11. Set the value to “350” as follows
Press the Large Coffee Button to increase the value
Press the Medium Coffee Button to decrease the value
Note
Each press of the Large or Medium Coffee will change the
displayed value by 1. (i.e. 347…348…349…350)
12. Press the Small Coffee Button 1 time, to store the value.
13. Turn the selector switch to the “Off” position.
14. Turn the selector switch to the On or On with Light position.
15. Prepare 4 coffees (medium size) one after the other.
16. When the fourth coffee is being dispensed, hold the sensor
probe directly in the flow of coffee. The temperature at the
coffee dispenser should be 171
o
F
- 194
o
F .
5.20 Brew Unit — Removal (in start/home position)
1. Open the door.
2. Remove the Waste Container.
3. Hold the handle and press on the part marked PRESS.
4. Gently pull outward on the Brew Unit to remove it from the
appliance.