Technical Information
89
The water is not
flowing through the
water path – check
pump operation and
water path for
obstructions.
Correct fault &
repeat test starting
at step 1.
5.43 Waterpath & Flowmeter - Testing
Caution
Hot water will flow from the water spout during this procedure
1. Fill the water reservoir
2. Place the appliance into the Service Mode with the Selector
Knob in the Programming position. (refer to section 6 for further
information on service mode access)
3. Press and hold all three coffee buttons; the display shows the
following:
5678
34
Does a pulsing (flickering) “8” appear in the top line of the display?
NO YES
Normal Operation – Proceed to step 6.
Does water flow from the Hot Water Spout?
NO YES
a. Unplug JP25 from the CPU Electronic
b. Place a jumper between pins 2 & 3
(figure 5-49).
c. Place the appliance into the Service
Mode with the Selector Knob in the
Programming position
Does the display show a solid “8”
in the top line of the display?
NO YES
Replace the electronic
Replace the flowmeter