Technical Information
66
CVA615 Coffee System
5.27 Brew Unit – Manual Reset to “Home Position”
(with brew unit not installed in appliance)
Refer to figure 5-24.
1. Press on the latch A; and press the funnel down B.
2. Push the connection piece to the far left position C.
3. Press "PRESS" once.
Figure 5-24: Moving the Brew Unit to “home position”.
4. The “Home” position (Figure 5-25) after resetting the Brew Unit.
The Brew Unit can now be reinstalled into the appliance.
Figure 5-25: Brew Unit in reset position.