EasyManua.ls Logo

Miele H350 - 6.2.6 Fault Code F13; 6.2.7 Fault Code F14

Miele H350
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Novotronic Models
Technical Information
59
6.2.6 Fault Code F13
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Replace the door lock cable
Cause:
The door-locking device (Pyrolitic) does not close because the door
temperature regulator is defective
Remedy:
Replace the door temperature regulator
6.2.7 Fault Code F14
Cause:
The door-locking device (Pyrolitic) does not close because its drive is
defective
Remedy:
Perform door lock manual override
Replace locking device
Cause:
The door-locking device (Pyrolitic) does not close because the door cable
is defective
Remedy:
Perform door lock manual override
Replace the door lock cable
Continued on next page.