67
6.3.7 Self Cleaning (Pyrolitic Mode) Can’t Be Switched Off
Symptom
After pyrolitic cleaning the unit cannot be switched off and a different
operating mode cannot be selected. “PYRO” remains in the display
Cause
Software fault in the electronic unit EPL 712
Parts required
Quantity Material Number Nomenclature
1 05290132 Electronic unit EPL 712
Remedy
Replace the Electronic unit
Note:
The unit can be used again after switching the main power off and on or
by resetting the clock. It can then be used normally until the next pyrolytic
cleaning cycle.