EMF DATA SHEET FOR ARC WELDING POWER SOURCE
Product/Apparatus Identification
Product
Stock Number
AUTO-CONTINUUM 350 CE 907660
AUTO-CONTINUUM 350 CE DI 907660001
AUTO-CONTINUUM 500 CE 907661
AUTO-CONTINUUM 500 CE DI 907661001
Compliance Information Summary
Applicable regulation Directive 2014/35/EU
Reference limits Directive 2013/35/EU, Recommendation 1999/519/EC
Applicable standards IEC 62822-1:2016, IEC 62822-2:2016
Intended use for occupational use for use by laymen
Non-thermal effects need to be considered for workplace assessment YES NO
Thermal effects need to be considered for workplace assessment YES NO
Data is based on maximum power source capability (valid unless firmware/hardware is changed)
Data is based on worst case setting/program (only valid until setting options/welding programs are changed)
Data is based on multiple settings/programs (only valid until setting options/welding programs are changed)
Occupational exposure is below the Exposure Limit Values (ELVs) YES NO
for health effects at the standardized configurations (if NO, specific required minimum distances apply)
Occupational exposure is below the Exposure Limit Values (ELVs) n.a YES NO
for sensory effects at the standardized configurations (if applicable and NO, specific measures are needed)
Occupational exposure is below the Action Levels (ALs) at the n.a YES NO
standardized configurations (if applicable and NO, specific signage is needed)
EMF Data for Non-thermal Effects
Exposure Indices (EIs) and distances to welding circuit (for each operation mode, as applicable)
Head
Trunk
Limb (hand) Limb (thigh)
Sensory
Effects
Health
Effects
Standardized distance 10 cm 10 cm 10 cm 3 cm 3 cm
ELV EI @ standardized distance
0.15
0.09
0.14 0.08 0.18
Required minimum distance 1 cm 1 cm 1 cm 1 cm 1 cm
Distance where all occupational ELV Exposure Indices fall below 0.20 (20%) 6 cm
Distance where all general public ELV Exposure Indices fall below 1.00 (100%) 115 cm
Tested by: Tony Samimi Date tested: 2016-08-05