Page 10 Accumass BW500 PL-565
Specifications
Outputs: mA: 1 programmable 0/4 - 20 mA, for rate, load and
speed output
optically isolated
0.1% of 20 mA resolution
750 Ω load max
see optional mA I/O board
load cell: 10 V dc compensated excitation for strain gauge
type, 4 cells max, 150 mA max
speed sensor: 12 V dc, 150 mA max excitation
remote totalizer 1: contact closure 10 - 300 ms duration
open collector switch rated 30 V dc, 100 mA max
remote totalizer 2: contact closure 10 - 300 ms duration
open collector switch rated 240 V ac/dc, 100 mA
max
relay output: 5 alarm/control relays, 1 form 'A' SPST relay
contact per relay, rated 5 A at 250 V ac, non-
inductive
Communications: two RS-232 ports
one RS-485 port
SmartLinx
®
compatible (see options)
Cable: one load cell:
non-sensing: Belden 8404, 4 wire shielded, 20 AWG or
equivalent, 150 m (500 ft) max
sensing: Belden 9260, 6 wire shielded, 20 AWG or
equivalent, 300 m (1000 ft) max
two / four* load cells:
non-sensing: Belden 9260, 6 wire shielded, 20 AWG or
equivalent, 150 m (500 ft) max
sensing: Belden 8418, 8 wire shielded, 20 AWG or
equivalent, 300 m (1000 ft) max
*for four load cell scale, run two separate cables of two load cell configuration
speed sensor: Belden 8770, 3 wire shielded, 18 AWG or
equivalent, 300 m (1000 ft)
auto zero: Belden 8760, 1 pair, twisted/shielded, 18 AWG,
300 m (1000 ft) max
remote total Belden 8760, 1 pair, twisted/shielded, 18 AWG,
300 m (1000 ft) max
Options: Speed Sensor: Mass Dynamics MD-36 / 36A / 256 or 2000A, or
RBSS, or compatible
Dolphin Plus: Milltronics Windows based software interface.
Refer to associated product documentation
SmartLinx
®
Modules: protocol specific modules for interface with
popular industrial communications systems.
Refer to associated product documentation.