Page 84 Accumass BW500 PL-565
Parameters
Communication (P750 - P792)
These parameters cover the various communications formats supported by the
BW500: serial printer, Dolphin Plus, SmartLinx
®
, and Modbus.
P750 P769 SmartLinx
®
Module Specific Parameters
These parameters are specific to the SmartLinx
®
module installed. Refer to the
module documentation for a list and description of the specific parameter
requirements.
P770 P789 Local Port Parameters
These parameters are specific to programming of the BW500 communication ports.
Refer to Communications for a listing and description of these parameters.
P790 SmartLinx
®
Error Status
Displays the results of ongoing hardware tests within the communications circuitry. If
any test does not meet the PASS requirements, communication halts and tests are
repeated until PASS requirements are met. Communication then resumes.
P791 SmartLinx
®
Protocol Status
P792 SmartLinx
®
Error Count
Displays the number or errors.
P799 Communications Control
Assigns programming control through the local keypad (or Dolphin Plus, P770 = 1),
or through a Modbus protocol (P770 = 2 or 3)
Entry:
0 = local
1 = modbus