PL-565 Accumass BW500 Page 9
Specifications
Specifications
Power: 100/115/200/230 V ac ±15%, 50/60 Hz, 31 VA
fuse, FU1: 2AG, Slo Blo, 2 A, 250 V or equivalent
Application: compatible with Mass Dynamics belt scales or equivalent 1, 2 or 4 load cell
scales.
compatible with LVDT equipped scales, with use of optional interface board
Accuracy: 0.1% of full scale
Resolution: 0.02% of full scale
Environmental: location: indoor / outdoor
altitude: 2000 m max
ambient temperature: -20 to 50 °C (-5 to 122 °F)
relative humidity: suitable for outdoor (Type 4X / NEMA 4X /IP 65
enclosure)
Installation category: II
pollution degree: 4
Enclosure: Type 4X / NEMA 4X / IP 65
285 mm W x 209 mm H x 92 mm D (11.2” W x 8.2” H x 3.6” D)
polycarbonate
Programming: via local keypad and/or Dolphin Plus interface
Display: illuminated 5 x 7 dot matrix liquid crystal display with 2 lines of 40
characters each
Memory: program stored in non-volatile FLASH ROM, upgradable via Dolphin Plus
interface
parameters stored in battery backed RAM,
battery P/N 20200035 or use Rayovac #BR2335, 3V, Lithium or equivalent,
5 year life
Inputs: load cell: 0 - 45 mV dc per load cell
speed sensor: pulse train: 0 V low, 5-15 V high, 1 to 2000 Hz,
or
open collector switch,
or
relay dry contact
auto zero: dry contact from external device
mA see optional mA I/O board
auxiliary 5 discrete inputs for external contacts, each
programmable for either: display scrolling,
totalizer 1 reset, zero, span, multispan, print,
batch reset, or PID function.