PL-565 Accumass BW500 Page 17
Installation
Interconnection
Note:
Wiring may be run via common conduit. However these may not be run in the
same conduit as high voltage contact or power wiring. Ground shield at one point
only. Insulate at junctions to prevent inadvertant grounding.
System Diagram
Note:
Typical system capability. Not all components or their maximum quantity may be
required.
belt scale,
see Specifications
speed sensor,
optional,
see Specifications
customer remote
totalizer
mA input from
customer device
relay output, to
customer device
ACCUMASS
BW500
optional SmartLinx
®
optional analog I/O
mA output to
customer device
mA output to
customer device
optional fieldbus
connection
communication
ports can be
configured for
Milltronics
Dolphin, print
data, or Modbus
ASCII or RTU
protocol