Page 72 Accumass BW500 PL-565
Parameters
Linearization Parameters (P390 - P392)
These parameters are used to compensate for non-linear response of the weighing
system to the BW500. Refer to Linearization on page 54 for execution, and example
on the use of these parameters.
Note:
In the case of multispan operation, the linearizer is applied to all spans.
P390 Linearizer
Enables or disables the linearization function.
Entry:
0 = off
f
1 = on
P391 Linearizer Load Points
Enters the load values, in units of P017, for the point selected, points 1 to 5 (P391-01
to –05). (f=0.00)
P392 Linearizer Compensation %
Enters the compensation value, in percent, for the point selected, point 1 to 5 (P392-
01 to – 05). (f=0.00)
P398 Moisture
Factors out moisture component of load, rate and total for all multispans selected.
The factored values are meant to report the dry mean values of the material being
conveyed. (f=0.00)
Enter the moisture content in % weight.