Page 64 Accumass BW500 PL-565
Parameters
P119 Override
This function allows the user to simulate an alarm condition: on or off, which will
override normal operation until P119 setting is returned to normal.
Values
P119 Condition Display (alarm field)
0 normal normal
1alarm on ALM #
2 alarm off blank