Page 80 Accumass BW500 PL-565
Parameters
P648 Totalizer Reset, Internal
Manual reset of the selected internal totalizer when the entry is made. (f=0)
Entry:
0 = no reset
1 = reset totalizer 2
2 = reset totalizers 1 and 2
Resetting the internal totalizers 1 and 2 resets the internal registers for external
totalizers 1 and 2.
P690 Speed Constant Entry
Selects the method by which the speed constant is entered.
1 = calculated, this selection returns the program to P015 for entry of speed constant,
either the value from the design data sheet
or
speed sensor pulses per revolution*
pulley circumference (m or ft) / revolution
2 = sensor data, the selection forwards the program to P691 and P692 for entry of
the required sensor data for automatic calculation. The calculated value is
automatically entered into P015
P691 Drive Pulley Diameter
For speed constant entry (P690 =2), this parameter is enabled for entry of the drive
pulley diameter.
Enter the pulley diameter in the units requested, mm if P004 = 2 and inches if P004 =
1.
P692 Pulses Per Sensor Revolution
For speed constant entry (P690 = 2), this parameter is enabled for entry of the pulses
per revolution that the speed sensor delivers.
Enter the pulses per revolution from the speed sensor nameplate