Chapter 4 Maintenance
4-13
1
2
2
4
5
6
Setting the Cleaning Intervals and
Type
The cleaning type and the interval between each cleaning
operation are set.
1
Press the
(MENU)
key in LOCAL.
MAINTENANCE MENU will be displayed.
2
Press , and press the key.
“AUTO MAINTENANCE” will be selected.
3
Press the several times to select
“Interval” or “Type”, and press the
key.
4
Press to select a set value, and
press the key.
Set value : The set value will differ according to
the ink type being used.
Set value of type : SOFT/ NORMAL/ HARD
5
Press the key several times
to endthe setting.
Fill up Ink
Supplies ink to correct nozzle clogging.
1
Press the
(MENU)
key in LOCAL.
MAINTENANCE MENU will be displayed.
2
Press timestwice, and press the
key.
“FILL UP INK” will be selected.
3
Press to select the filling type.
Soft : Use this in cases where head cleaning
will not achieve recovery, such as when
multiple clogged nozzles occur or
nozzle cluster dropout occurs.
Normal : Use this if nozzle cluster dropout occurs
in initial ink filling.
Hard : Use this in cases where the dumper has
become empty, such as in dumper
replacement.
4
Press the key.
If you selected “Soft” in step 4, a Select Fill Up
Color screen will be displayed.
If you selected “Normal” or “Hard”, go to step 6.
5
Press to select the filling color,
and press the key.
6
Press the key.
Ink is supplied automatically.
7
Press the key several times
to end the setting.