Operation Principle
2-13
If the filling is not 4-color, or if the filling is 4-color and switching is not possible within 1 supply system,
the warning for the current supply cartridge is displayed. The followings are relations between warnings
and operations.
*1 Transition to the LOCAL mode is executed after each completion of drawing.
*2 In case of a month next to the ink expiration month, transition to the LOCAL mode is executed after each completion of
drawing.
Local/Remote idle warning
display
(state of supply system unit)
Guidance function warning
display in detail
(state of cartridge unit)
Cleaning Filling Drawing
NEAR END INK NEAR END

*1
INK END
INK END
!CAR
NO CARTRIDGE
NON-ORIGINAL INK
WRONG INK IC
Kind of INK
Color of INK
WRONG CARTRIDGE
Expiration:2MONTH
Expiration:1MONTH
*2
Expiration
