Color Inkjet Printer JV33-130/160
2-36
SKEW CHECK
Skewing of media is checked.
When media is not detected, an operation error (ERROR30) is displayed.
Feed distance is designated to execute feeding.
Feed distance: 1~500 m (unit: 1 m)
During the feeding, remaining of feed distance is displayed with unit of 10 mm.
[END]
: Feeding abort,
[ENTER]
: Start feeding again.
Cut jig function
After the Skew check starts, (feed distance is not designated) the following operation starts the cut jig
function.
[REMOTE]
[FUNCTION]
The cut jig function repeats media cut feed with designating feed distance and number of cut times.
Number of cut times is displayed in count down during cut.
Feed distance: 10~10000 mm (unit: 10 mm Default: 500 mm)
Number of cut times: 1~1000 count (unit: 1 count Default: 25 count)
TEMPERATURE.CHK
<Temperature check test>
Item Content
HEAD TEMP. Environment temperature of head is displayed (A/D value is also displayed).
Displaying of head temperature uses a unit selected in the UNIT SETUP of the MACHINE SETUP.
NOZZLE TEMP. Nozzle temperature error check is executed.
At Normal: OK is displayed
At error: NG is displayed
HEAT SINK TEMP. Temperature of HDC board heatsink is displayed (A/D value is also displayed).
Displaying of heatsink temperature uses a unit selected in the “UNIT SETUP of the
MACHINE SETUP.
SLIDER TEMP. Temperature read from the thermistor on the slider PCB is displayed (A/D value is also displayed).