GPI Channels
GPI Signal name Type GPI Pin No
44-way
GPI Pin No
25-way
1 GPI1 IN/OUT 42 25
2 GPI2 IN/OUT 12 12
3 GPI3 IN/OUT 41 24
4 GPI4 IN/OUT 11 11
5 GPI5 IN/OUT 40 23
6 GPI6 IN/OUT 10 10
7 GPI7 IN/OUT 39 22
8 GPI8 IN/OUT 9 9
9 GPI9 IN/OUT 38 21
10 GPI10 IN/OUT 36 19
11 GPI11 IN/OUT 6 6
12 GPI12 IN/OUT 35 18
13 GPI13 IN/OUT 5 5
14 GPI14 IN/OUT 34 17
15 GPI15 IN/OUT 4 4
16 GPI16 IN/OUT 33 16
GND GND GND 13, 32 13, 15
Create a GPI Macro
To create a macro, display the relevant GPI then press enter. If the GPI is
unused >Empty< will be displayed on the front panel.
Press enter again to gain access to the entire Imagestore 750 Operate
menu.
Using the joystick arrows W X display the first command to be added to the
macro and press enter to add it. The display is now returned to the listing of
the macro, showing the added command. To add a second command, use the
joystick arrows W X to display the next command and press enter as before.
Further commands are added to the macro using the same procedure.
Approximately 200 command lines may be added to the macro.