1010
APPX
Appendix 15 Added and Enhanced Functions
"Use MC/MCR to Control EN" of
subroutine-type FB
F:
S: 1.040S
F: 28
S: 1.035M
 GX Works3 Operating Manual
MELSEC iQ-R Programming
Manual (Program Design)
Program restoration information write
selection
F:
S: 1.040S
F: 31
S: 1.040S
In process
mode
F: 13
S: 1.040S
In redundant
mode
F: 15
*7
S: 1.045X
*7
F: 13
*9
S: 1.045X
*9
Page 942 Program Restoration
Information Write Selection
File batch online change of FB files
and the global label setting file
F:
S: 1.040S
F: 31
S: 1.040S
F: 13
S: 1.040S
Page 119 File batch online
change
File batch online change when the
program memory does not have
enough free space
F:
S: 1.040S
F: 31
S: 1.040S
F: 13
S: 1.040S
Page 119 File batch online
change
Storage of logging data in the function
memory
F:
*1
S:
O: 1.76E
*4
F: 31
S:
O: 1.76E
*4
Page 183 Storage location of
data logging files
Data logging file transfer function F: 06
*1
S:
O: 1.76E
*4
F: 31
S:
O: 1.76E
*4
Page 194 Data Logging File
Transfer (Auto Transfer to FTP
Server)
Extension of points for safety input
device and safety output device
 F:
S: 1.040S
F: 04
S: 1.019V
Page 548 Safety device area
setting range
Page 554 List of safety
devices
MELSEC iQ-R CPU Module
User's Manual (Startup)
Auto logout time change of the user
authentication function (5 minutes
60 minutes)
 F:
S:
F: 04
S:
Safety communication function using
the simple motion module
*8
 F: 07
S: 1.030G
MELSEC iQ-R Simple Motion
Module User's Manual
(Application)
Error detection invalidation setting F: 05
S:
F: 35
S:
F: 14
S:
Page 132 Error detection
invalidation setting
Local device and label specification for
target data/condition specification of
the data logging function
F: 05
*1
S: 1.045X
O: 1.82L
*4
F: 35
S: 1.045X
O: 1.82L
*4
Page 170 DATA LOGGING
FUNCTION
Battery-less option cassette F: 35
S: 1.045X
Page 394 Latch with Battery-less
Option Cassette
iQ Sensor Solution functions for CC-
Link
Data backup/restoration
*5
F: 05
*1
S:
F: 35
S:
iQ Sensor Solution Reference
Manual
Online change (SFC block) F: 05
*10
S: 1.045X
*10
F: 35
*11
S: 1.045X
*11
MELSEC iQ-R Programming
Manual (Program Design)
Access level "Assistant Developers" of
the user authentication function
 F: 13
S: 1.045X
GX Works3 Operating Manual
Omission of writing files that are not
changed
F: 05
S: 1.045X
F: 35
S: 1.045X
F: 13
S: 1.045X
GX Works3 Operating Manual
Device test with execution conditions F: 06
S: 1.047Z
F: 38
S: 1.047Z
Page 157 Device test with
execution conditions
Added or enhanced function F: Firmware version of the CPU module
S: Software version of the engineering tool
O: Version of the other tools
Reference
R00/R01/
R02CPU
Rn(EN)CPU RnPCPU RnPSFCPU
and
R6PSFM
RnSFCPU
and
R6SFM

Table of Contents

Related product manuals