APPX
Appendix 5 List of Special Register Areas
863
A
*1 The CPU module where this function can be used supports these special register areas.
*2 These CPU modules do not support Data logging file transfer error causes for the data logging settings No.2 to No.10 (SD1227,
SD1237, SD1247, SD1257, SD1267, SD1277, SD1287, SD1297, SD1307).
SD1217 Data logging setting
No.1
Data logging file
transfer error cause
Data logging file
transfer error cause
An error cause that is detected last in the data logging file transfer
function or a transferring of data logging files to the data memory is
stored.
0: No error
Other than 0:For details on the values stored when an error occurs,
refer to the list of error codes. ( Page 703 List of error
codes)
This register is cleared to 0 when data logging is started.
S (Error) Rn
*1
SD1220
to
SD1227
Data logging setting
No.2
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1230
to
SD1237
Data logging setting
No.3
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1240
to
SD1247
Data logging setting
No.4
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1250
to
SD1257
Data logging setting
No.5
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1260
to
SD1267
Data logging setting
No.6
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1270
to
SD1277
Data logging setting
No.7
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1280
to
SD1287
Data logging setting
No.8
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1290
to
SD1297
Data logging setting
No.9
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
SD1300
to
SD1307
Data logging setting
No.10
Same configuration
as the setting No.1
Data configuration is the same as the setting No.1 (SD1210 to
SD1217).
Same
configuration
as the setting
No.1
Rn
*1
RnP
*2
RnSF
*2
No. Name Data stored Details Set by
(setting
timing)
CPU