APPX
Appendix 8  Buffer Memory
897
A
*1 Data is stored at END processing where the value is changed.
*2 When the count exceeds 65535, counting is continued from 1 again.
*3 A slave station specified is being disconnected, the information immediately before the disconnection is stored.
Un\G1053 
to 
Un\G1064
Diagnostic information 1
*3
Diagnostic information 1 When 1 (valid) is stored in b0 to b7 of Un\G1052, the number of 
occupied stations, group number, IP address, the accumulated number 
of timeouts, and the accumulated number of disconnection detection 
are stored. When 0 (invalid) is stored in b0 to b7 of Un\G1052, 0 is 
stored.
■Un\G1053: Number of occupied stations
■Un\G1054: Group number
■Un\G1055: IP address (lower)
■Un\G1056: IP address (upper)
1 to 4: First octet to fourth octet
When the IP address has not been set in the parameter, 0 is stored.
■Un\G1063: Accumulated number of timeouts
After the END instruction of the scan where the bit 0 of 'Diagnostic 
information display request' (Un\G1050) is turned off and on is 
executed, the accumulated number of timeouts that occurred in a slave 
station specified in 'Diagnostic request information' (Un\G1051) is 
stored.
• 0: No timeouts
• 1 to 65535: Number of timeouts (accumulated number)
*2
■Un\G1064: Accumulated number of disconnection detection
After the END instruction of the scan where the bit 0 of 'Diagnostic 
information display request' (Un\G1050) is turned off and on is 
executed, the accumulated number of disconnections that detected in 
a slave station specified in 'Diagnostic request information' (Un\G1051) 
is stored.
• 0: No disconnections
• 1 to 65535: Number of disconnection detection (accumulated 
number)
*2
S (Status 
change)
Un\G1068 
to 
Un\G1077
Diagnostic information 2
*3
Diagnostic information 2 When Diagnostic information 2 is valid (1 is stored in b8 to b15 of 
Un\G1052), the manufacturer code, model code, device version, 
module information, error code, and detailed module information are 
stored. When Diagnostic information 2 is invalid (0 is stored in b8 to 
b15 of Un\G1052), 0 is stored.
■Un\G1068: Manufacturer code
■Un\G1070: Model code (lower)
■Un\G1071: Model code (upper)
■Un\G1072: Device version
■Un\G1074: Module information
■Un\G1075: Error code
■Un\G1076: Detailed module information (lower)
■Un\G1077: Detailed module information (upper)
S (Status 
change)
Address Name Data stored Details Set by 
(setting 
timing)
3
1
4
2
b15 to b8 b7 to b0
Un\G1055