APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
Number of logging lines
The following window specifies the number of records to be output before and after trigger occurrences when the trigger
logging is selected ( Page 182 Number of records)
Window
Displayed items
Item Description Setting range Default
No. of records (before
trigger)
Specify the number of records to be output as pre-trigger record. SD memory card: 0 to 999999
Function memory: 0 to 49999
1
No. of records (after
trigger)
Specify the number of records to be logged during and after a trigger
occurrence.
SD memory card: 1 to 1000000
Function memory: 1 to 50000
1
Total No. of records View the total number of pre-trigger and post-trigger records. 2