978
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
Displayed items
*1 Date and/or time can be added in any format by using the following character strings.
Year: YYYY for four-digit expression; YY for two-digit expression
Month: MM
Day: DD
Day of the week: ddd (Sunday: Sun, Monday: Mon, Tuesday: Tue, Wednesday: Wed, Thursday: Thu, Friday: Fri, Saturday: Sat)
Hour: hh
Minute: mm
Second: ss
Example: for June 18, 2014 (Wednesday), 09:30:15, YYYYMMDDdddhhmmss 20140618Wed093015_00000001.bin
Also when using the additional information simply as a character string rather than the above format, any character string can be added
by enclosing it with double-quotation marks (" ").
Example: when adding the character string "address" to the file name, "address" address_00000001.bin can be used.
*2 Maximum of 64 one-byte characters (including an underscore (_), a serial number (eight digits), a period, and an extension) can be
used.
However, when a character string that contains double quotation marks (" ") is specified, the maximum number reduces by the number
of the double quotation marks.
In the Process CPU (redundant mode), since three characters of an identifier are added to a file name at system switching, the save file
name should be within 61 one-byte characters (including underscores (_), a serial number (eight digits), a period, and an extension).
( Page 500 Switching to a storage file)
*3 Reducing the setting value results in frequent file switching, so that it is possible that the scan time and/or the device/label access
service processing time can be extended.
Item Description Setting range Default
Logging
file save
setting
File save destination Specify the storage folder for the data logging file. 60 characters or less
(double-byte character not
allowed)
LOG (setting
No.)
Folder to store file to be saved Select information to be added to the name of the folder
which stores the storage file.
Not checked
File name Simple setting Select information to be added to the name of the
storage file.
Checked
Optional setting Specify information format to be added to the name of the
storage file.
*1*2
Add date type Add date/time when the file switching condition is
satisfied and when the file is created if the optional
setting is selected.

File
switching
setting
Number of
files to be
saved
Number of files to
be saved
Specify the maximum number of storage files. 1 to 65535 1
Operation when
exceeds the
number of files
Select the operation when the number of storage files
exceeds the maximum number specified. ( Page 192
Action to take when the maximum number of storage files
is exceeded)
•Overwrite
•Stop
Overwrite
File
switching
timing
*3
Number of records Select the timing at which the file is replaced with new
one. ( Page 190 File switching condition)
When "Number of records" is selected, the file is
replaced when the number of records exceeds the
specified value.
When "File size" is selected, the file is replaced when the
file size exceeds the specified size.
SD memory card: 1 to
65500
Function memory: 1 to
12000
File size SD memory card: 10 to
16384K bytes
Function memory: 10 to
1024K bytes