970
APPX
Appendix 13 How to Use CPU Module Logging Configuration Tool
Displayed items
*1 This item is displayed when "Device" is specified as "Logging target" in the "Logging type" window.
*2 This item is displayed when "Label" is specified as "Logging target" in the "Logging type" window.
*3 When the input label name is valid, it is used as it is. Therefore, the case may differ between the label name defined in the engineering
tool and the label name displayed on the window.
*4 The label that cannot be watched in the engineering tool cannot be set.
*5 If an array element is not specified, it is handled as the start of the array ([0]). (Example: When "bLabel1[0..9]" exists and "bLabel1" is
input, it is handled as "bLabel1[0]".)
*6 If the input array is out of the range, an undefined value is specified.
Item Description Setting range Default
No. In this column, the data setting numbers from 001 to 128 are displayed. 
Device
*1
Head Specify the start device number.
To specify a local device, use "Program name/#Device name". (Example:
"MAIN/#M1")
Page 171 Data to be
collected
Last In this column, the end device number calculated based on the data type
and size is displayed.
Label
*2
Set a target label.
*3*4
When setting a global label
Input "Label name".
Example: "label_w1"
For the label of timer type/retentive timer type/counter type, specify the
element name. (S: contact, C: coil, N: current value)
Example: "label_w1.S"
When setting a local label
Input "Program block name/Label name".
Example: "ProgPou/label_w1"
For the label of timer type/retentive timer type/counter type, specify the
element name. (S: contact, C: coil, N: current value)
Example: "ProgPou/label_w1.S"
When setting a structure element
Input "Label.Element name".
For the label of timer type/retentive timer type/counter type, specify the
element name. (S: contact, C: coil, N: current value)
Example: "tmLabel.S"
When setting an array element
Input "Label name[Element number of third dimension][Element number of
second dimension][Element number of first dimension]".
*5*6
When setting a structure array member
Input "Label name[Element number of third dimension][Element number of
second dimension][Element number of first dimension].Member name".
*5*6
Data type Select the type of data to be collected.
When a label is selected as the target data, the data type corresponding to
the data type of the label is displayed.
Page 171 Data type
Size [Byte] Specify the data size when the data type is set to "String" or "Raw". 1 to 256 bytes
Output type Clicking the [...] button at the rightmost part of each row displays the
"Output Format (integer/float)" window. Select the format to be used when
data is output to the file.
Page 950 Data output type