36 ERROR CODES
36.4 List of Error Codes
31B2H SFC program
block, step
specification
error
The specified step exceeds the range
that can be used in the SFC program.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Turn on SM321 (Start/stop SFC
program) if it is off.
Error location
information
At instruction
execution
31B3H SFC program
block, step
specification
error
The number of simultaneous active
block steps that can be specified in
the SFC program exceeds the
permissible value.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Error location
information
At instruction
execution, at
SFC program
execution
31B4H The total number of simultaneous
active steps that can be specified in
the SFC program exceeds the
permissible value.
At instruction
execution, at
SFC program
execution
31B5H A SET Sn/BLm\Sn and RST Sn/
BLm\Sn instruction were specified for
the self step in the step operation
output.
At instruction
execution
3200H Program
execution error
Memory/Device Setting set in the
CPU parameters differ from those
assigned to the sequence programs,
FB programs, and global label setting
file. (After Memory/Device Setting
were modified, only the CPU
parameters were written to the CPU
module.)
Stop After Memory/Device Setting are
modified, write the sequence
program file(s), FB file(s), and
global label setting file together
with the CPU parameter file to the
CPU module.
If no global label is used, delete
the global label setting file.
Drive/file
information
At power-on, at
RESET, at
STOP RUN
state
3201H Program
execution error
Even though no program is set in the
CPU parameters, multiple program
files exist.
Stop Set a program in the CPU
parameter.
Delete unnecessary program files.
Drive/file
information
At power-on, at
RESET, at
STOP RUN
state
3202H Program
execution error
The program file is incorrect. Or, the
program file is not written properly.
For the subroutine type FB, "Use MC/
MCR to Control EN" of "Inherent
Property" is set to "Yes".
Stop Write the program file to the CPU
built-in memory again.
Set "Use MC/MCR in EN Control"
in "Inherent Property" of
subroutine-type FB to "No" and
write the program file to the CPU
built-in memory again.
Replace the CPU module with the
one that supports the use of the
subroutine-type FB for which "Use
MC/MCR in EN Control" of
"Inherent Property" is set to "Yes".
Dr
ive
/file
information
At power-on, at
RESET, at
STOP RUN
state
3203H Program
execution error
No program file exists. Stop Check if the system parameter file,
CPU parameter file, and program
file exist.
Write the system parameter file,
CPU parameter file, and program
file to the CPU built-in memory.
Drive/file
information
At power-on, at
RESET, at
STOP RUN
state
3204H Program
execution error
Two or more SFC programs were
executed.
Stop Ensure that only one SFC
program is executed.
Drive/file
information
At SFC
program
execution
Error
code
Error name Error details and cause Stop/
continue
Action Detailed
information
Diagnostic
timing