EasyManua.ls Logo

Mitsubishi Electric MELSEC iQ-R Series - Page 585

Mitsubishi Electric MELSEC iQ-R Series
760 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36 ERROR CODES
36.4 List of Error Codes
583
36
3192H SFC program
configuration
error
A self step number was specified for
the specification destination step
number for the jump transition.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Take measures to reduce noise.
Write the SFC program to the
CPU module again. Then, reset
the CPU module and run it again.
If the same error code is displayed
again, the possible cause is a
hardware failure of the CPU
module. Please consult your local
Mitsubishi representative.
Error location
information
At SFC
program
execution
3193H A self step number was specified for
the specification destination step
number for the reset step.
31A0H SFC program
block, step
specification
error
An attempt was made to start an SFC
program block that was already
running.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Turn on Start/stop SFC program
(SM321) if it is off.
Error location
information
At SFC
program
execution
31A1H SFC program
block, step
specification
error
A non-existent SFC program block
was specified.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Turn on SM321 (Start/stop SFC
program) if it is off.
Check the SFC program has
existed.
Check the execution status of the
SFC program.
Error location
information
At instruction
execution, at
SFC program
execution
31A2H SFC program
block, step
specification
error
The specified block exceeds the
range that can be used in the SFC
program.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Turn on SM321 (Start/stop SFC
program) if it is off.
Error location
information
At instruction
execution
31B1H SFC program
block, step
specification
error
A non-existent SFC program step was
specified.
Stop Check the detailed information
(error location information) of the
error by executing module
diagnostics using the engineering
tool, display the error program
(step) by clicking the [Error Jump]
button, and correct the program.
Turn on SM321 (Start/stop SFC
program) if it is off.
Check the SFC program has
existed.
Check the execution status of the
SFC program.
Error location
information
A
t
instruction
execution, at
SFC program
execution
Error
code
Error name Error details and cause Stop/
continue
Action Detailed
information
Diagnostic
timing

Table of Contents

Other manuals for Mitsubishi Electric MELSEC iQ-R Series

Related product manuals