142
4 OPERATION CONTROL PROGRAMS
4.6 Bit Operations
Bit right shift: >>
Setting data
Usable data
: Usable
Description, data type of result
Processing details
The data specified with (S1) is shifted to the right by the number of times specified with (S2).
If the most significant bit of (S1) is 1, 1 enters the most significant bit of the right shift result. If the most significant bit of (S1)
is 0, 0 enters the most significant bit of the right shift result.
When (S1) is a 16-bit integer type and (S2) is a negative number or not less than 16, the result is 0.
When (S1) is a 32-bit integer type and (S2) is a negative number or not less than 32, the result is 0.
Operation error
An operation error will occur if:
(S1) or (S2) is an indirectly specified device and its device No. is outside the range.
Program example
Program which shifts #0 two bit positions to the right and substitutes the result to D0
Format Number of basic steps Usable steps
F/FS G
(S1) >> (S2) 7 
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(S1) 
(S2) 
Setting data Description Data type of result
(S1) Data to be right-shifted Data type of (S1) (Integer type)
(S2) Number of right shifts
D0 = #0 >> K2
0#0 111111
b15 b0
0D0 000100101001101
b15 b0
000000 000