4 OPERATION CONTROL PROGRAMS
4.17 Vision System Dedicated Function
255
4
Close line: MVCLOSE
Setting data
Usable data
: Usable
Description, data type of result
Processing details
The vision system specified with (S) is logged off (disconnected). The status storage device value set in the Ethernet
communication line setting parameter is 0 (not connected).
MVCLOSE instruction is not operated for the vision system which is not logged on (not connected).
Operation error
An operation error will occur if:
The (S) data is outside the range of 1 to 32.
The vision system parameter setting is different from the setting on the vision system.
Program example
Program which logs off the vision system of the vision system (camera) 1
Format Number of basic steps Usable steps
F/FS G
MVCLOSE(S) 6 
Setting
data
Usable Data
Bit
device
Word device Constant Calculation
expression
Bit
conditional
expression
Comparison
conditional
expression
16-bit
integer
type
32-bit
integer
type (L)
64-bit
floating
point
type (F)
16-bit
integer
type
(K/H)
32-bit
integer
type
(K/H, L)
64-bit
floating
point
type (K)
(S) 
Setting data Description Data type of result
(S) Vision system (camera) No. to log off (1 to 32)
MVCLOSE K1