4 OPERATION CONTROL PROGRAMS
4.17 Vision System Dedicated Function
253
4
[Direct specification]
If the floating-point data is transferred to the vision system, it is handled as 32-bit floating-point data. The
number of effective digits is approx. 7 digits. Data in the seven digits or later may not match the (S3) data.
(S4) is set in increments of 10ms. When the setting is omitted, the timeout time is 10 seconds (same as setting 1000).
Operation error
An operation error will occur if:
The (S1) data is outside the range of 1 to 32.
The number of character string of spreadsheet cell or tag specified with (S2) outside the range of 1 to 32 bytes.
The spreadsheet cell or tag specified with (S2) does not exist.
The data type of spreadsheet cell or tag specified with (S2) is different from data format specified with (S3).
The (S3) data is outside the range.
The (S4) data is outside the range of 1 to 32767.
The vision system specified with (S1) has not been logged on.
The vision system parameter setting is different from the setting on the vision system.
The reading data is not completed when the specified timeout time has elapsed.
Program example
Program which transfers the floating-point value stored in D3000F to the tag
"Calib_1.World_Point0.X" of the vision system (camera) 1
Data type specified with (S3) Setting example
16-bit integer value type K12345
32-bit integer value type K12345678L
64-bit floating-point type K1234.5
Character string “MITSUBISHI”
MVOUT K1, "Calib_1.World_Point0.X", D3000F