4 OPERATION CONTROL PROGRAMS
4.19 Other Instructions
275
4
Program example
2 words from #0 are written to buffer memory address 0H of the intelligent function module
(First I/O No.: 010H) on the RIO axis 603 of the SSCNET/H head module
RTO K603, H01, H0, #0, K2, M10
100
#0
200
#1
0H
1H
100
200
Device memory
SSCNET
µ
/H head module (RIO Axis No.603)
Intelligent function module
(First I/O No.: 010H)
Buffer memory
2 words
transfer
RST M10
RTO K603,H01,H0,#0,K2,M10
M10
[F10]
[G10]