278
4 OPERATION CONTROL PROGRAMS
4.19 Other Instructions
Program example
1 word is read from the buffer memory address 10H of the intelligent function module (First I/
O No.: 020H) on the RIO axis 602 of the SSCNET/H head module, and is stored in W0
RFROM W0, K602, H02, H10, K1, M0
M0
[F20]
[G20]
RST M0
RFROM W0,K602,H02,H10,K1,M0
100
W0 10H
11H
100
200
SSCNET
µ
/H head module (RIO Axis No.602)
Intelligent function module
(First I/O No.: 020H)
Buffer memory
300
Device memory
1 word
transfer