EasyManuals Logo

Mitsubishi MELSEC User Manual

Mitsubishi MELSEC
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
A - 14
6.12.3 Relationship of remote operation and CPU's RUN/STOP status
6.13 Monitor Function
6.14 Writing in Program during CPU Module RUN
6.14.1 Online change in ladder mode
6.15 Watchdog Timer(WDT)
6.16 Remote password
6.17 CPU Module System Display by GX Developer
6.18 LED Display
6.18.1 Method to turn off the LED
CHAPTER7 COMMUNICATION WITH INTELLIGENT FUNCTION MODULE
7.1 Communication with CC-Link Safety master module
7.2 Communication with CC-Link IE Controller Network Module or MELSECNET/H Module
7.3 Communication with Ethernet Module
7.4 Communication using intelligent function module dedicated instructions
CHAPTER8 PARAMETERS
8.1 PLC Parameters
8.2 Network Parameters
8.3 Remote Password
CHAPTER9 DEVICE EXPLANATION
9.1 Device List
9.2 Internal User Devices
9.2.1 Input (X)
9.2.2 Output (Y)
9.2.3 Internal relay (M)
9.2.4 Annunciator (F)
9.2.5 Edge relay (V)
9.2.6 Link relay (B)
9.2.7 Link special relay (SB)
9.2.8 Timer (T)
9.2.9 Counter (C)
9.2.10 Data register (D)
9.2.11 Link register (W)
9.2.12 Link special register (SW)
9.3 Internal System Devices
9.3.1 Special relay (SM)
9.3.2 Special register (SD)
9.4 Nesting (N)
9.5 Constants
9.5.1 Decimal constant (K)
9.5.2 Hexadecimal constant (H)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC and is the answer not in the manual?

Mitsubishi MELSEC Specifications

General IconGeneral
CategoryProgrammable Logic Controller (PLC)
ManufacturerMitsubishi Electric
SeriesMELSEC
Programming LanguagesLadder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), Instruction List (IL), Sequential Function Chart (SFC)
Communication ProtocolsEthernet, CC-Link, RS-232, RS-485, USB, Profibus, Modbus
Model SeriesFX, Q, L, iQ-R, iQ-F
Input Voltage100-240V AC, 24V DC (varies by model)
Memory CapacityVaries widely depending on the CPU module and series. Ranges from kilobytes to megabytes.
I/O Points16 to 8192 points (varies by model)
Communication PortsEthernet, RS-232, RS-485, USB (varies by model)
Programming SoftwareGX Works2, GX Works3, GX Developer
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57Hz, 0.075mm amplitude; 57 to 150Hz, 9.8m/s² acceleration
Shock Resistance147m/s², 3 times in each direction (X, Y, Z)
Protection ClassIP20 (varies by model)
CPU Processing Speed0.02μs to 0.1μs per instruction (varies by model)