56
5 Specifications
No. 99MAF029B
Operating humidity range 20 to 80% RH (with no condensation)
Storage temperature
range
–10 C to 50 C
Storage humidity range 5 to 90% RH (with no condensation)
CE marking EMC Directive EN61326-1
Immunity test requirement: Clause 6.2 Table 2
Emission limit: Class B
RoHS Directive EN50581
*1
The indication accuracy and repeatability indicate the values obtained from the height measurement
of a flat surface using the standard ø5 stepped probe. In the case of diameter, maximum (minimum)
value, displacement, or circular pitch measurement, the measured value may be larger than the
accuracy ratings listed in the table due to variation in the measuring force during the scanning
measurement compared to the height measurement.
*2
Perpendicularity indicates the value that is obtained from the measurement of a flat surface placed
parallel with the datum base using the Lever Head (MLH-521) and Mu-checker (M-551).
*3
A communication driver is required.
It can be downloaded from our homepage. http://www.mitutoyo.co.jp/global.html
For details, please refer to the instruction manual.
*4
To use models equipped with the air-float function, use a surface plate of JIS1 Class or above. If a
scratched or uneven surface is used, the specified performance may not be achieved.
*5
The AC adapter cannot be used to recharge rechargeable batteries.
*6
The life of the battery will vary depending on how the product is used.
Recommended nickel hydride batteries: 1,900 mAh or greater capacity