NICE5000 User Manual 7 Description of Function Codes
- 169 -
•
4: Nuisance judged by light-load signal
If the light-load signal is active, the system determines that nuisance exists when the
number of car calls is greater than a certain value.
When the system determines that the elevator is in the nuisance state, it cancels all car
calls. In this case, call calls need to be registered again.
Function Code
Parameter Name Setting Range
Default Unit Property
F8-09
Rated elevator load 300–9999
1000 kg ★
It is used to set the rated elevator load. This parameter is used for the anti-nuisance
function.
Function Code Parameter Name Setting Range Default Unit Property
F8-10
Logic program control 0–65535
0 - ★
It is used to select the elevator functions. Each bit of the function code denes a function, as
described in the following table.
If a bit is set to 1, the function indicated by this bit is enabled; if this bit is set to 0, the
function is disabled.
The functions dened by the binary bits are described in the following table.
Bit Function Description Default
Bit13
Hiding
uncommon
parameters
If this function is enabled, the operation panel does not
display the following uncommon parameters:
F1-12 to F1-24
F4-08 to F4-119
F7-08 to F7-10
F9-12 to F9-14
FA-12 to FA-14
Fb-01
FH-21 to FH-29
Fr-01 to Fr-28
0
Function Code Parameter Name Setting Range Default Unit Property
F8-14 Local address
0–127
0: broadcast address
1 - ★
It is used to set the communication address of the elevator.
Function Code Parameter Name Setting Range Default Unit Property
F8-18 Overload percentage 100–130 110 % ★
F8-19 Full-load percentage 70–110 80 % ★
F8-20 Light-load percentage 10–50 30 % ★