NICE5000 User Manual 7 Description of Function Codes
- 179 -
It is used to set the door open holding time when there is a car call. The elevator closes the
door immediately after receiving a door close command.
Function Code Parameter Name Setting Range Default Unit Property
Fb-17 Door open holding time at base oor 1–30 10 s ☆
It is used to set the door open holding time after the elevator arrives at the base oor. The
elevator closes the door immediately after receiving a door close command.
Function Code Parameter Name Setting Range Default Unit Property
Fb-18
Door open delay 10–30000
30 s ☆
It is used to set the door open holding time when there is door open delay input. The
elevator closes the door immediately after receiving a door close command.
Function Code Parameter Name Setting Range Default Unit Property
Fb-19
Special door open holding time 10–1000
30 s ☆
It is used to set the door open holding time when there is a disability call.
Function Code Parameter Name Setting Range Default Unit Property
Fb-20
Manual door open holding time 1–60
10 s ☆
It is used to set the door open limit delay in the case of manual door. This parameter is valid
when the manual door function is used.
Group FC: Brief Fault Information
Function Code Parameter Name Setting Range Default Unit Property
FC-00
Designated fault 0–99
0 - ☆
It is used to designate the fault to be monitored.
The designated fault code is saved in parameters of group E9, and will not be overwritten.
Function Code
Parameter Name Setting Range
Default Unit Property
FC-01
20th fault code 0–6299
0 - ●
FC-02
20th fault subcode 0–65535
0 - ●
FC-03
20th fault month and day 0–1231
0 MM.DD ●
FC-04
20th fault hour and minute 0–2359
0 HH.MM ●
FC-05
20th fault information 0–65535
0 - ●
···
FC-46
11th fault code 0–6299
0 - ●