EasyManuals Logo

Monarch NICE 5000 User Manual

Monarch NICE 5000
233 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
7 Description of Function Codes NICE5000 User Manual
- 180 -
Function Code
Parameter Name Setting Range
Default Unit Property
FC-47
11th fault subcode 0–65535
0 -
FC-48
11th fault month and day 0–1231
0 MM.DD
FC-49
11th fault hour and minute 0–2359
0 HH.MM
FC-50
11th fault information 0–65535
0 -
These parameters record the rst 10 faults of the elevator among the last 20 faults.
The fault code is a 4-digit number. The two high digits indicate the oor where the car is
located when the fault occurs, and the two low digits indicate the fault code. For example,
the FC-46 is 0835, indicating that when the 11th fault (Err35) occurs, the car is near oor 8.
The fault subcode is used to locate the causes of the fault. The specific fault time is
recorded in month, day, hour and minute.
Group Fd: Parallel Control Parameters
Function Code Parameter Name Setting Range Default Unit Property
Fd-00
Number of elevators in
parallel control
1–3
1 -
Fd-01
Elevator No. 1–3
1 -
These parameters are used to set the number of elevators and elevator No. in parallel
control mode.
The NICE5000 supports a maximum of three elevators through CAN interface, and is
compatible with one NICE3000 system in the parallel control system.