7 Description of Function Codes NICE5000 User Manual
- 176 -
Bit Function Description Default
Bit3
Cancelling
monitoring at
leveling and
slow-down
During normal running, the system keeps comparing the
position at action of the leveling/slow-down signal with the
position obtained through shaft auto-tuning. If the deviations is
too large, the system reports the related fault.
If this function is enabled, the system will not detect the
deviation or report the fault.
0
Bit4
Slow-down stuck
detection
After detecting that the slow-down signal is stuck, the system
reports fault Err45.
0
Bit5
Canceling 45s
time limit at shaft
auto-tuning
The shaft auto-tuning time is not restricted by the motor 45s
running time limit.
0
Bit6
Leveling
adjustment
If this function is enabled, adjustment in group Fr parameters
is valid.
0
Group Fb: Door Function Parameters
Function Code Parameter Name Setting Range Default Unit Property
Fb-00
Number of door machine(s) 1–2
1 - ★
It is used to set the number of door machine(s).
Set this parameter based on actual conditions.
Function Code Parameter Name Setting Range Default Unit Property
Fb-01
Door function selection 0–65535
0 - ●
It selects the door control and display functions. Each bit of the function code defines a
function, as described in the following table.
Bit Function Setting Bit Function Setting
Bit0
Hall call
button display
1
Independent for
front door and back
door
Bit1
Car call
button
display
1
Independent for
front door and back
door
0
Consistent for front
door and back door
0
Consistent for front
door and back door
Bit2
Hall call door
open mode
1
Corresponding door
open
Bit3
Car call door
open mode
1
Corresponding door
open
0
Both doors open
0
Both doors open
Bit8
Door open
button display
1
Independent for
front door and back
door
Bit9
Door close
button
display
1
Independent for
front door and back
door
0
Consistent for front
door and back door
0
Consistent for front
door and back door